Which Aico Alarm Do I Need? A Room by Room Guide

Aico make a lot of alarms with very similar names. Ei3016, Ei3014, Ei3024, Ei3028. Pick the wrong one for a room and you get false alarms, or worse, an alarm that's too slow for the fire it's meant to catch.

This is the quick way to choose, room by room.

Quick answer

Optical smoke (Ei3016) for halls and landings, multi-sensor (Ei3024) for living rooms and bedrooms, heat (Ei3014) for the kitchen and garage, and CO (Ei3018, or Ei3028 for a kitchen) wherever there's a boiler, gas hob or burner. Link them all together.

The four sensor types

  • Optical smoke. Quick to spot slow, smouldering fires, the kind that start in a sofa or bedding. Best for halls, landings and living areas.
  • Heat. Goes off when the room gets hot enough (58°C on the Aico heat alarms we stock). It ignores cooking smoke and steam, so it's the right choice for kitchens and garages.
  • Multi-sensor (optical and heat). Uses both sensors together, so it reacts to a wider range of fires with fewer false alarms. A good fit for living rooms and bedrooms.
  • Carbon monoxide (CO). Detects CO gas, not fire. It goes in rooms with a boiler, gas hob, log burner or other fuel-burning appliance.

Room by room

Room What to fit Aico 3000 Series
Hall and landing Optical smoke Ei3016
Living room Optical smoke or multi-sensor Ei3024
Bedrooms Optical smoke or multi-sensor Ei3024
Kitchen Heat Ei3014
Kitchen with gas boiler or hob Heat and CO Ei3028
Room with a log burner or boiler CO Ei3018
Garage Heat Ei3014

If you want one head that does everything in a room, the Ei3030 combines optical, heat and CO sensors.

How many do you need?

BS 5839-6, the British Standard for home fire alarms, sets out levels of cover called categories:

  • LD3: smoke alarms on escape routes only (halls and landings). The bare minimum.
  • LD2: LD3, plus the main living room and a heat alarm in the kitchen. The recommended minimum for most homes.
  • LD1: alarms in every room where a fire could start, apart from bathrooms and toilets.

For a typical two storey house to LD2, that's a smoke alarm in the hall, one on the landing, one in the living room and a heat alarm in the kitchen, all linked. Add CO where there's a fuel-burning appliance.

Mains or battery?

BS 5839-6 also sets grades for how alarms are powered. For rented homes and new builds it recommends Grade D1: mains powered with a sealed back-up battery that lasts the life of the alarm.

The 3000 Series meets that. Each alarm runs on 230V mains with a 10-year rechargeable lithium back-up cell, so there's no battery to change and nothing for a tenant to pull out.

Older Aico models like the Ei146e smoke alarm and Ei144 heat alarm are mains powered with a replaceable 9V alkaline back-up. They suit like-for-like swaps on an existing system.

Landlords in Wales have extra legal rules on top of this. See smoke and CO alarm rules for rented homes in Wales.

Linking them together

Interlinked alarms all sound when one detects a fire, so you hear it wherever you are in the house. There are two ways:

  • Hard wired. An interconnect cable runs between the alarms. Best when you're doing first fix or a rewire.
  • Wireless. Fit an Ei3000MRF SmartLINK module to each 3000 Series alarm and they link by radio. Ideal where you can't run new cables, like an occupied rental.

Two handy extras: the Ei450 alarm controller lets you test, locate and silence a radio-linked system from one place, and the Ei1529RC control switch does the same job on a hard-wired one.

Everything above shows live stock from our Bridgend branch. Browse the full range in Aico smoke, heat and CO alarms.

Frequently asked questions

What's the difference between the Aico Ei3016 and Ei3024?

The Ei3016 has an optical smoke sensor only. The Ei3024 has optical and heat sensors together, which gives a wider fire response with fewer false alarms, so it suits living rooms and bedrooms.

Can I put a smoke alarm in the kitchen?

It's not recommended. Cooking smoke and steam set them off. Use a heat alarm like the Ei3014, or the Ei3028 if the kitchen also has a gas boiler or hob.

Do Aico 3000 Series batteries need replacing?

No. They have a sealed rechargeable lithium back-up cell designed to last the 10-year life of the alarm. You replace the whole alarm at 10 years.

Can I mix wired and wireless Aico alarms?

Aico design their RadioLINK products to work with each other, but check compatibility for your exact models before mixing systems.

Not sure what a job needs?

Tell the Bridgend counter the rooms and fuel types and they will put the list together for you.